Installation Instructions - A-Plus Air
For replacement applications using an existing uncased A-coil plenum installation follow Procedure 3C. For new applications using a KCAKC N-coil kit casing follow Procedure 3D. For new applications using a field-fabricated plenum installation follow Procedure 3E. Procedure 3 — Installation of Evaporator Coil UNIT OR PROPERTY DAMAGE HAZARD ... Access Content
How To Flip A Carrier Bryant "A" Frame HVAC Coil.mp4 - YouTube
David Hahn from Hahn's Air Specialists on Hilton Head, SC demonstrates how to flip a carrier / bryant "A" frame coil from a factory horizontal left position to a horizontal right position. ... View Video
For Cooling Coils CONDENSATE TRAPS
Accumulating condensate to drain off while preventing air from entering a draw-thru unit or escaping a blow-thru unit. A cooling coil’s drain-pan opening is located at the point in an airflow system where the air pressure— either positive or negative—is the greatest. It makes sense to prevent an air “leak” at this location, ... Retrieve Content
PRODUCT DATA DIGEST CHILLED WATER FAN-COIL UNITS - carrier.com.kw
FAN-COIL UNITS QUALITY SYSTEM • Insulated & painted condensate drain pan and a factory fitted frame complete with filter media. (Cu/Al) evaporator coil for maximum heat transfer. • Carrier Lanced Sine Wave fin pattern ensures energy efficient performance. ... Access Doc
50TJM-24AxAxxxAxAS 20 945 2,050 96x88x54 . Evaporator Coil. Coil Type Qty x Rows x FPI* Qty x Face Area (ft. 2) Coil test Pressure . Drain Pan connection Size (in) Return Air Filter Qtyx Size (in) Evaporator Fan and Motor Section. Fan Quantity / Fan Size (in) Fan Type. ... Read Here
ASPEN EVAPORATOR COIL INSTALLATION INSTRUCTIONS
ASPEN EVAPORATOR COIL INSTALLATION INSTRUCTIONS NOTE: These instructions are for the use of qualified individuals trained and drain pan using four (4) screws directly into the side of the secondary drain pan overlapping attachment flanges. Use one (1) screw per flange. ... Get Content Here
Evaporator Coil - Southern Pipe & Supply
Evaporator Coil IM-HAC-0966540-12 December 2013 ADP evaporator coils are designed for use with AC the opposite side of the coil (Note: horizontal drain pan must have drain plugs tightly closed in the rear of the unit). Remove the top plate. ... Content Retrieval
INSTALLATION INSTRUCTIONS Evaporator Coils, Multipoise
INSTALLATION INSTRUCTIONS Evaporator Coils, Multipoise EAM4X18−60 tip coil toward condensate drain. Coil casing need not be secondary drain or external condensate pan, the unit requires servicing or water damage will occur. ... Fetch Content
TECHNICAL DESCRIPTION - UPGNET
Rust-proof plastic drain pans - The vertical and horizontal drain pans on these coils are made of a fiberglass reinforced thermoset polymer that will not rust or compromise stability at high tempera-tures. Insulated Cabinet - Evaporator coil cabinets are thermally insu-lated with foil faced insulation to prevent sweating. HD coils use ... Fetch This Document
Product Data - Sigler Commercial
Carrier’s versatile packaged air-handling units satisfy Pitched drain pan can be adjusted for a right--hand or evaporator coil and condensate pan surfaces. Economy The 40RU Series packaged air handlers have low initial costs, and they continue to save money by providing ... Fetch Content
18-AH36D1-1 Installer’s Guide A341869P13
1. The drain hole in the drain pan must be cleared of all insulation. 2. Insulate the drain line to prevent sweating and dripping. It is always recommended that an auxiliary drain pan be installed under a horizontally installed evaporator coil or 90% gas furnace. Connect the auxiliary drain line to a separate drain line (no trap is needed in ... Access Document
HVAC - Wikipedia
Since the evaporator operates at a temperature below the dew point, moisture in the air condenses on the evaporator coil tubes. This moisture is collected at the bottom of the evaporator in a pan and removed by piping to a central drain or onto the ground outside. ... Read Article
Fan coil Unit - Wikipedia
A fan coil unit (FCU) is a simple device consisting of a heating and/or cooling heat exchanger or 'coil' and fan. It is part of an HVAC system found in residential, commercial, and industrial buildings. ... Read Article
Product Data - Carrier® - Acondicionadores De Aire: Aire ...
The FB4C fan coil has the proven technology of Carrier fan coil EVAPORATOR COIL Face Area (sq. ft) 2.23 2.97 2.97 4.45 5.93 7.42 Airflow above 400 cfm/ton on 048---061 size could result in condensate blowing off coil or splashing out of drain pan. 12 PERFORMANCE DATA (cont.) GROSS ... Get Content Here
Indoor Coil Cleaning - YouTube
In this video I show how to clean a coil of the indoor unit and all the surrounding areas. Keeping your coil clean and the filter replaced will ensure you are getting the most out of your unit. ... View Video
INSTALLATION MANUAL - Thermo Pride
Inspection by the carrier’s agent should be made in writing. See Local Distributor for more information. Check drain pan for cracks or break-age. CLEARANCES. DURING INSTALLATION. Clearance must be provided for: 1. Refrigerant piping and connections 2. Maintenance and servicing access - including cleaning the coil 3. Condensate drain line 4. ... Fetch Document
FA4B Product FB4B Data Direct Expansion Fan Coil
1. Airflow based upon dry coil at 230v with factory approved filter and electric heater (2 element heater, sizes 018 through 036; 3 element heater, sizes 042 through 060). 2. To avoid potential for condensate blowing out of drain pan prior to making drain trap: —Return static pressure must be less than 0.4 in. wc ... Retrieve Content
Section L4 - Evaporator Coils - Home | Totaline
(FRTP - sloped - drain pan/pans Plastic - sloped - drain pans w/ brass inserts • Uncased coil designed to fit the industry furnaces • Split delta plates Limited Parts Warranty (with registration) 10 year Limited Parts Warranty 5 year — R-22 Foil faced insulation • UV light knockouts in cabinets from the factory ... Access Document
HORIZONTAL 2-WAY CASED EVAPORATOR COIL INSTALLATION INSTRUCTIONS
When the evaporator coil is installed in an attic, above a finished ceiling, or in any location where cond ensate overflow would result in property damage, the installer must provide an auxiliary drain pan in addition to the primary and secondary drains. The auxiliary drain pan must be connected to a drainage system separate from the primary ... Retrieve Content
PRODUCT DATA DIGEST CHILLED WATER FAN-COIL UNITS - carrier.com.kw
• Insulated & painted condensate drain pan and a factory fitted frame complete with filter media. • Installed with direct driven forward curved centrifugal fans and 3 speed motor ensures quiet operation. • Standard copper tube aluminium fins (Cu/Al) evaporator coil for maximum heat transfer. ... Doc Retrieval
Central Air Conditioner Leaks Water On Floor: Part ... - YouTube
The "P trap" in my Central Air was clogged with dirt and debris. This caused AC to freeze and leaked water on the floor. I replaced the P trap and cleaned the drain hole and it works great again. ... View Video